Celestia TTI has a wide portfolio of standard OMTs solutions, from very low frequency up to V band. Celestia TTI can also develop custom solutions as per customer´s requirements at different frequency bands.
The following parameters define OMT performance for system integration. Celestia TTI’s engineering team provides full specification sheets on request for each standard product and custom design.
| Parameter | Typical Performance |
|---|---|
| Frequency Coverage | Very low frequency to V band (standard portfolio) |
| Polarisation Modes | Dual linear, dual circular (with polariser) |
| Port-to-Port Isolation | ≥40 dB (Ku band typical); ≥45 dB achievable with optimised designs |
| Insertion Loss | Low — waveguide technology minimises ohmic loss |
| Return Loss | >15 dB across operating band (design dependent) |
| Common Port Interface | Circular waveguide |
| Output Port Interfaces | Rectangular waveguide (band-specific) |
| Operating Environments | Cryogenic (4 K) to ambient temperature |
| Custom Options | Frequency band, waveguide standard, polarisation mode, cryogenic compatibility |
Contact Celestia TTI for detailed specifications on specific models and custom configurations.
An orthomode transducer is a waveguide component that serves to combine or separate two orthogonally polarised microwave signal paths — commonly referred to as a polarisation duplexer. Wikipedia In any antenna system handling dual-polarisation signals, the OMT is the critical junction between the feed horn and the transmit and receive chains: it separates the orthogonal polarisations with high isolation, protecting sensitive receiver front-ends from the power of the transmit signal while allowing both paths to share a single antenna aperture.
Celestia TTI manufactures a wide portfolio of standard OMT solutions covering very low frequencies through V band, and develops fully custom solutions to customer specifications at any frequency band. The same precision manufacturing expertise that underpins Celestia TTI’s feed horn and polariser families is applied to OMT design — ensuring low insertion loss, high polarisation isolation, and mechanical compatibility with adjacent feed chain components.
Few manufacturers offer OMT solutions spanning from the lowest microwave frequencies through millimetre-wave V band. Celestia TTI's portfolio covers this complete range, providing a consistent engineering partner across wideband and multi-band antenna systems regardless of operating frequency.
In Ku band, a typical OMT provides approximately 40 dB isolation between polarisation ports — ensuring only 0.01% of the transmitter's output power is cross-fed into the receiver path. Wikipedia Celestia TTI's precision CNC-machined waveguide structures achieve the tight dimensional tolerances required to maintain high isolation across the full operating bandwidth.
OMTs destined for radio astronomy and deep space receiver applications must operate reliably at temperatures down to 4 K inside cryostats, without mechanical failure from thermal contraction or degraded RF performance at low temperatures. Celestia TTI designs cryogenic-compatible OMTs for integration into receiver systems where the full feed chain is cooled.
Beyond the standard portfolio, Celestia TTI's engineering team develops OMTs for non-standard frequency bands, waveguide interfaces, polarisation configurations, and physical form factors. This capability is particularly valuable for scientific telescope projects, satellite payload programmes, and antenna test range installations where standard catalogue products cannot meet system-specific requirements.
Celestia TTI designs OMTs as part of complete feed chain solutions — mechanically and electrically compatible with the corrugated feed horns, polarisers, and LNAs the company also manufactures. This integrated design approach eliminates interface mismatch between components and simplifies system-level validation.
Waveguide OMT performance is directly dependent on dimensional accuracy. Celestia TTI's manufacturing processes, certified under ISO 9001:2015, deliver the mechanical precision required to meet tight return loss and isolation specifications at millimetre-wave frequencies where tolerances are measured in microns.
OMTs do not perform in isolation — their performance depends on mechanical and electrical compatibility with the feed horn, polariser, LNA, and waveguide transitions they connect to. Celestia TTI’s position as a manufacturer of the complete passive feed chain means OMTs are designed with this system context built in.
Celestia TTI designs and manufactures corrugated feed horns, polarisers, OMTs, and the cryogenic and warm LNAs that follow them. This scope allows co-optimisation of the complete chain rather than treating each component independently.
Celestia TTI has supplied cryogenic OMT and feed chain components for radio telescope projects including SKA receiver development. This experience with the most demanding low-noise receiver requirements informs the precision and cryogenic compatibility of the standard product range.
From UHF to V band, and from standard waveguide interfaces to bespoke cryogenic assemblies, Celestia TTI’s engineering team develops custom OMTs for applications where catalogue products cannot meet system requirements.
Consistent quality and full traceability across every component — from prototype through series production — backed by Celestia TTI’s certified quality management system.
OMTs are used in dual-polarised VSAT terminals, earth station antennas, and ground station feed systems where the transmit and receive signals share the same feed horn — providing the isolation that prevents the high-power uplink signal from saturating the sensitive LNB or LNA on the receive path. Celestia TTI's OMTs integrate directly with the BUC, LNB, and feed horn components of SATCOM ground terminals across C, Ku, Ka, and DBS bands.
Cryogenic radio astronomy receivers require OMTs cooled to 4–20 K inside the cryostat, positioned between the corrugated feed horn and the cryogenic LNAs. As discussed in the Radio Astronomy Receivers section of this site, Celestia TTI designs and manufactures complete cryogenic receiver chains including the OMT — ensuring the passive feed components are mechanically and thermally compatible with the cryostat and LNA assembly.
Modern deep space network receivers employ OMTs to enable simultaneous processing of both polarisations MDPI from a single antenna feed, expanding both the science return and the TT&C capability of each ground station contact. OMTs for deep space applications must meet stringent phase and amplitude balance requirements to enable polarimetric measurements and coherent VLBI processing.
Dual-polarisation waveguide feed chains are a key sub-system in most RF satellite payloads as well as reflector-based ground antennas, with OMTs enabling polarisation diversity and multiple frequency operation across transmit and receive bands. ESA High-throughput satellite (HTS) systems with hundreds of feed chains place a premium on compact OMT designs — an area where Celestia TTI's custom engineering capability delivers solutions tailored to payload physical constraints.
An OMT separates or combines two electromagnetic signals that share the same waveguide but have orthogonal polarisations — typically horizontal and vertical linear, or left-hand and right-hand circular. In a satellite antenna feed, it connects the single circular port of the feed horn to two separate rectangular waveguide ports: one for the transmit chain (BUC or SSPA) and one for the receive chain (LNA or LNB). The high isolation between these ports — typically 40 dB or more — prevents the high-power transmit signal from entering the receive path.
The standard portfolio includes full-band OMTs in Q/U/V band (millimetre wave), K/Ka band, and up to 18 GHz. Custom solutions are available at any frequency band from very low microwave frequencies through V band. Contact Celestia TTI with your specific frequency and performance requirements for availability and lead time.
An OMT separates or combines two orthogonally polarised signals in rectangular waveguide — handling linear polarisation directly. A waveguide polariser converts between linear and circular polarisation by introducing a controlled phase shift between the two orthogonal field components. In antenna feed chains requiring circular polarisation, a polariser is typically placed between the feed horn and the OMT, with the OMT then separating the resulting orthogonal linear polarisations into the transmit and receive paths.
Yes. Celestia TTI designs cryogenic-compatible OMTs for integration into radio astronomy and deep space receiver cryostats operating at temperatures down to 4 K. Cryogenic OMT designs account for thermal contraction of materials, mechanical interface compatibility with the cryostat structure, and RF performance verification at operating temperature.
Standard rectangular waveguide interfaces (WR series) are available for the product bands listed. Custom waveguide interfaces — including non-standard flange types, circular waveguide transitions, or coaxial outputs — can be specified for applications with particular integration requirements. Contact the engineering team with your interface specifications.
A typical feed chain assembly — from front to back — comprises: corrugated or smooth-wall feed horn → (optional) polariser → OMT → separate transmit and receive waveguide paths to the BUC/SSPA and LNA/LNB. Celestia TTI manufactures all of these components and can supply a complete, pre-integrated feed chain assembly tested as a system rather than as separate components.